The other poster is correct in that the master breaker may be elsewhere. It will be on the path of the two big wires coming put of the top there, wherever it is they go in your house. Probably right on the other side of where the incoming line goes through the wall.
But I actually came here to say I have never once in my life shut off the master to replace a breaker. Remove the hot wire from the dud breaker first and then that circuit is dead. Just don't touch the bus bar in the back of the box and you'll be fine.
If you suspect shenenegans re: things being hot that shouldn't be, you can verify with your multimeter or voltage probe before touching anything.