this post was submitted on 24 Nov 2023
2 points (100.0% liked)
Home Networking
229 readers
7 users here now
A community to help people learn, install, set up or troubleshoot their home network equipment and solutions.
Rules
- Please stay on topic.
- Please use the search function to look for keywords related to what you want to ask before posting since most common issues have been answered.
- No Ads. This community is for support and discussion. Ads and self promotion are not welcome here.
- No product reviews or announcements. If you have a question about a product, be specific about what you want to know.
- Be civil. Don't be a jerk. Not being a jerk is surprisingly easy.
- No URL shorteners. URL shorteners tend to hide the real use of a link. For this reason, please use normal links, even if they're long.
- No affiliate links.
- No gatekeeping. With profession shall come professionalism. Extend help without judging others for their ignorance. The same goes for downvoting of comments or posts for "stupid questions" or not being as knowledgeable as others.
founded 1 year ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
You have assumed the word 'ground' without an always required adjective. Numerous grounds exist. For transient protection of appliances, only 'earth' ground matters.
The concept first demonstrated by Franklin over 250 years ago. Surges (lightning is only one example) are hunting for earth ground. How that current connects to earth defines damage.
A most common incoming path is AC mains. Once anywhere inside, then that transient hunts for earth destructively via appliances. A most common destructively path is into networked hardware on AC mains. Then out to earth via networking hardware.
Damage is often on the outgoing path - ie an ethernet or HDMI port.
If any wire enters without making a low impedance (ie less than 10 foot) connection to single point earth ground, then protection is compromised.
Protection only exists when a surge is not anywhere inside.
Ethernet must make that low impedance (ie hardwire has no sharp bends or splices) connection via a protector. Coax cable has best protection without any protector. Only a hardwire makes a low impedance (ie less than 10 foot) connection to same earthing electrodes. Every wire inside every incoming cable (without exception) must make that earth ground connection.
How good is protection? Defined by that connection to and quality of earth ground electrodes. Wall receptacle safety ground is all but disconnected - never is an earth ground. Number of electrodes may be dependent on factors such as geology.
Products from APC do not claim effective protection. One need only read specification sheets. How does its hundreds or thousands joules 'absorb' a surge that can be hundreds of thousands of joules? How do 2 cm protector parts 'block' what three miles of sky cannot?
Scams target consumers who ignore these and other numbers. No protector claims protection. Either it makes that low impedance (ie hardwire not inside metallic conduit) to single point earth ground. (All four words have electrical significance.) Or may give a surge more paths to earth via nearby appliances.
Type 3 (plug-in) protectors cannot be anywhere near earth ground. To not try to do much protection. To avert what tiny joules protectors do - fire.
Don't take my word for it. Professionals have been both saying and doing this stuff for over 100 years. Only recently have companies such as APC been selling magic boxes to consumers who ignore numbers and all this well proven science.